When the facts count.
Technical Data
Control Panel
- Frames from 16 + 8 faders to 192 + 16 faders
- Remote frames of 16 and 32 faders
- 6 banks per 2 layers
- 100 mm faders + 8 rotary controls with free assignment + Input-Gain Control; channel display for every fader with sense-triggered change of module display in the channel display
- TFT metering mono, stereo or 7.1 including bus assignment, gain reduction for dynamics, AfV status, VCA assignment
- Output of GUI pages, e. g. metering, to external screen
- Console lighting per fader bay
- Colour coding per fader, setting per snapshot
- Fader notch, PFL overpress
- 33 user buttons
- Optional: script tray, PPM integration, TB microphone integration
- 2 U or 5 U 19’’ integration
Signal Processing
- 512 channels and 144 summing buses, 40-bit floating point
- Up to 376 inputs with A/B input, 48 sub groups, 32 aux sends, 96 track busses, 48 main sums, change on the fly from mono to stereo to surround channel and bus
- Up to 64 surround channels, 128 VCA groups, 256 GPC channels
- Surround formats: DTS/Dolby Digital 5.1, Dolby Pro-logic 4.0, DTS ES / Dolby EX 6.1, SDDS 7.1, DTS-HD 7.1; various panning characteristics, surround aux bus
- Loudness metering: full integration in mc² mixing consoles - see below
- AMBIT: conversion of stereo signals to surround sound
- 2* AFL: 1* surround 8-channel, 1* stereo
- 2* stereo PFL
- Audio-follow-Video with 128 events, control via Remote MNOPL protocol, GPI or matrix connect, adjustable envelope with up to 10 s fade time
- Solo In Place
- Permanent input metering on the fader; selectable metering of INPUT, PF, AF, DIROUT, on the channel display
- Modules: INMIX with MS Decoder, digital amp, 2-band fully parametric filter, 4-band fully parametric EQ, 2-band fully parametric sidechain filter, insert, delay up to 1800 ms (units in metres, milliseconds, frames); 4 independent dynamics modules: Expander, Gate, Compressor, Limiter; Image, Meter, Direct Out
- Inline configuration with send/return switching – on the channel or global
- 128 VCA masters with metering of up to 8 slaves
- Fully-equipped surround channel with linking of all channel parameters and Hyper Panning
- AMBIT upmix with normal channel latency, available for every surround channel
- Loudness Metering compliant to EBU R128 & ATSC/A85, available for every surround, stereo or mono channel; integrated for every sum and group
Routing Matrix
- Up to 8192 crosspoints, non-blocking
- 96 kHz, 24 bit
- Fully redundant signal path
- Level adjustment for all inputs and outputs
- Downsizing up to 7.1 to Stereo
- Integrated monitoring options for remote workplaces like e. g. director’s room
- Full networking of up to 16 HD Cores, share and import of sources and destinations, studio arbitration function
- Full snapshot and production portability independent of matrix or DSP size
- Level control for every input and output
Loudness Metering *
- Full integration of loudness metering complying with ITU-R BS.1770
- Compatible with international recommendations like EBU R128 and ATSC A/85
- International recommendations are stored as preset, they can be adapted anytime
- Available in any channel strip
- Different visualisations can be defined per channel:
- Classical peak meter
- Loudness meter
- Combination of peak and loudness meter displays true peak and loudness complying with ITU-R BS.1770
- Long-term measurement in all summing channels
- Exposed display of the measured values in the GUI header
- Absolute and relative visualisation of the scales and measured values
- EBU +9, EBU +18 and ITU-R BS.1771 scales
- True peak metering complying with ITU-R BS.1770 displays true peak values
- The time slots Momentary (400ms) and Short-Term (3s) can be defined individually for all input and summing channels
- Using additional LFE measuring and selectable gating settings prepared for future norms
*available with V4.14 SW Release
Plugin Server
- Full VST plugin integration with storage of plugin parameters in snapshots and production data
Static and Dynamic Automation
- Snapshot automation, several sequences with trim and fade
- Dynamic TC automation, recording per parameter, recording of all channel modules incl. Bus Assign, writing data in stop mode, Touch, Glide, Join, Punch In/Out
Interfaces
- Mic/Line with up to 127 dB dynamic range, subsonic filter 40, 80, 140 Hz Line Out, Adat® (ADAT® is a registered trademark of Alesis, LLC and is used here under license)
- AES with input and output SRC, transparent Dolby E routing, balanced and unbalanced
- HD-SDI with up to 270 ms delay on board, MADI 64 & 56 with fibre or coax, ATM, GPIO, Serial, MIDI, RAVENNA AoIP, Dolby En-/Decoder Plug-In
- Direct intercom connection
- All interfaces with 24 bit, 96 kHz (for details see DALLIS product information)
- Monitoring systems stereo and surround
Synchronisation
- Two redundant inputs with automatic detection of Blackburst, Wordclock, AES3, MADI
Redundancy
- PSUs, DSP card, router card
- Fully redundant signal path
- Redundant control system, replaceable during runtime, full data redundancy
- PSU for control system and control panel
Control
- Bay-Iso with separate layer and bank switching, plus second PFL/AFL bus
- Global A/B input switching
- Enhanced mix-minus (N-M) control with independent off-air conference
- Fader control of all level parameters
- Various tally and faderstart modes
- Programme switch
- Machine control
- Audio-follow-Video, up to 128 camera tallies, Ethernet or GPI-controlled
- Manifold T/B integration
- Remote control of camera microphone via GPI or phantom power
External Control Systems
- Remote control of all routing parameters via network
- Remote control of monitoring units of remote positions
- Remote control of the integrated router monitor units
- Remote of signal parameters like SDI, Silence Detects, Mic Gain etc. (for details see documentation RemoteMNOPL)
- Remote control via network
- Online configuration via AdminHD; graphic configuration of HD Core components
- External matrix control for BFE, VSM, Evertz, Miranda, Sony, and others
- iPhone App
Remote Maintenance
- Connection via Internet Remote Software
- Software updates, error diagnostics, remote
- mxGUI: remote controle of console via laptop
Subject to change without prior notice, no responsibility is taken for the correctness of the details provided.